ModuTEMP® 70 Modular Resistance and Thermocouple Temperature Sensors
- Measuring resistor
1x / 2x Pt100,
thermocouple 1x / 2x “J“, “K“, “N“
- Measuring range
-200 to +700 °C (Pt100),
-200 to +800 °C (“J“),
-200 to +1300 °C (“K“, “N“)
- Accuracy class
A, B according to EN 60751,
1, 2 according to EN 60584-1
- Stem material
stainless steel 1.4541, 1.4401, 2.4816, Nicrobell/Pyrosil
- Extension piece (thermowell) material
stainless steel 1.4541
- Protective tube material
stainless steel 1.4541, 1.4845, 1.4762,
Kanthal AF
- Optional headmounted transmitter with output 4 to 20 mA, HART, Profibus, Fieldbus, including version with galvanic isolation and intrinsically safe version
- Housing IP 65, IP 68
- Intrinsically safe version
(Ex) II 1/2G Ex ia IIC T6…Tx°C Ga/Gb
(Ex) II 1/2D Ex ia IIIC T200 85°C…T200 x°C Da/Db.
- Flameproof enclosure
(Ex) II 1/2G Ex db IIC T6...Tx°C Ga/Gb.
- Protection by enclosure
(Ex) II 1/2D Ex ta/tb IIIC T90°C…Tx°C Da/Db.
Links and documentation:
|
|